io.github.industrial-aiops/iaiops · 13 stars · Python · MIT

MCP server Governed OT data tap: 15 field protocols + cross-protocol RCA brain; audit + MOC gating.

Install

The repo has no one-line install. Follow its README.

Published as

  • PyPIiaiopsstdio

From the server's entry in the official MCP Registry.

Open the repo

Configuration

NameSet asWhat it is
IAIOPS_MCPRequiredEnv varTool-menu selection: comma-separated protocols or a named profile (e.g. 'fab', 'process', 'building', 'opcua,modbus'). No default since 0.10.0 — unset prints the selection menu and exits; set to a profile name (e.g. factory) or comma-list of protocols.
IAIOPS_CONFIGOptionalEnv varPath to the endpoints config YAML (default: ~/.iaiops/config.yaml).
IAIOPS_MASTER_PASSWORDOptional · SecretEnv varMaster password unlocking the encrypted secret store (~/.iaiops/secrets.enc).
IAIOPS_NO_EGRESSOptionalEnv varSet to 1 to withhold every data-shipping tool (message bus, external historian, remote LLM) from list_tools() at registration time, for an airgap/sealed-box deployment. This is a data-exfiltration axis only, not read/write authorisation — whether a write is allowed is the caller's decision, and every call (read or write) is audited. Gates MCP tools only — not a firewall.

Files

README.md

Industrial-AIOps

English · 中文

Ask an AI agent why the line stopped — and get an answer that cites its evidence.

A vendor-neutral, read-first data tap for the factory floor. It speaks 15 field protocols, correlates what it reads across them, and hands your agent an evidence-cited verdict instead of a guess. Every call is audited, and no reading ever phones home.

pip install "iaiops[opcua]"      # pick your protocol — or [all]
iaiops init                      # write ~/.iaiops/config.yaml
iaiops doctor                    # check the setup before you trust it

Prefer a container? The published image is cosign-signed and runs non-root. It speaks MCP over stdio, so keep stdin open and mount a volume for the audit store:

cosign verify --key deploy/margo/cosign.pub ghcr.io/industrial-aiops/iaiops:0.33.0-factory
docker run -i --rm -v iaiops-state:/home/iaiops/.iaiops \
  ghcr.io/industrial-aiops/iaiops:0.33.0-factory

For a hardened or air-gapped deployment (read-only rootfs, cap_drop: ALL, no-new-privileges, optional on-box LLM) use deploy/margo/compose.yaml and deploy/airgap/. The analysis engine needs no GPU and no model API — it is deterministic; an LLM is optional and only phrases the verdict.

What you get

Reads OPC-UA (+ Historical Access, tag auto-discovery) · Modbus TCP/RTU · S7comm · Mitsubishi MC · Omron FINS · MTConnect · MQTT/Sparkplug B · EtherNet/IP · EtherCAT · PROFINET · SECS/GEM · HART-IP · BACnet/IP · IO-Link · serial ASCII instruments (RS-232/485, serial device servers) — plus read-only REST layers for BAS supervisors (Metasys / Niagara) and Ignition Gateway
Figures out downtime root cause (the flagship copilot), alarm floods (ISA-18.2), broken dataflows, data trustworthiness, OEE, asset inventory, legacy PLC program explainer (ST/AWL/L5X)
Governs audit · budget · risk-tier · undo — on every call, through one engine, from both MCP and CLI
Stays yours no telemetry or phone-home by default. Six tools can send data off-box by design (stream_publish, stream_publish_event, uns_publish, historian_push, mqtt_publish, rca_narrate) — IAIOPS_NO_EGRESS=1 withholds all six for an air-gapped posture. A future-release Margo option exports only process health and audit counts to an explicitly configured local/private OTLP collector; it is also blocked by IAIOPS_NO_EGRESS=1.

Eleven editions ship in this package — ten per industry (fab · factory · process · building · water · warehouse · clinical · pharma · renewables · plcnext), each adding its own read-only advisory checks, and one cross-protocol: sensor (connect, decode and read a sensor; IAIOPS_MCP=sensor). Substation / utility telecontrol (IEC-104 · DNP3 · IEC-61850) ships separately as iaiops-energy.

Your first five minutes

Four commands. Only one of them touches a device: doctor probes each configured endpoint (iaiops doctor --skip-probe contacts nothing).

pip install "iaiops[modbus]"     # pick the protocol you actually have, or [all]
iaiops onboard status            # ← run this first. Contacts NOTHING.
iaiops doctor                    # config, secrets, reachability — and the version
iaiops readiness                 # every scenario, and what each gap needs

onboard status answers the smaller questions you have first: which journey is this site on — reading its devices directly, or subscribing to a UNS broker its data already flows through — which step of it are you on, and what is the one command that advances it? It is derived from your store and config.yaml every time. The one thing it keeps is a namespace audit verdict, and that counts only for the broker and topic filter it was taken on and always shows its age — so edit config.yaml by hand and the answer stays true.

readiness reads your config and local store and answers one question: which scenarios can this site run today, and what does each gap need? Every gap comes with the command that closes it, ranked by how much it unlocks. No agent, no cloud, no account, and nothing on the wire.

Then the path, in the order that matters — survey what is there, take a bounded sample, and only then explain it:

contacts a device?
Survey iaiops scan plan → iaiops scan run preview sends nothing; the run itemises every packet class it sent
Configure iaiops onboard draft → you merge it into config.yaml no — it reads the stored scan, and writes nothing
Tap iaiops collect run line1 --duration 7d yes — and it reports what it saw and what it missed
Declare iaiops tags export → a person fills in role → iaiops tags apply --by <you> no — the role column comes out empty on purpose
Explain iaiops oee measure --since … --until … · iaiops investigate open · iaiops diag rca no — all over collected history

See the whole thing run against a real device in about two minutes, including a genuine mid-run outage, with ./demo/oee-line/run_demo.sh — no hardware, no configuration, nothing written outside a temporary directory. demo/oee-line/ explains what each step is for and what the numbers do and do not claim.

Why read-first

OT is exactly where you want an agent on a tight leash. The read paths are the product; the few write paths are OT-dangerous, off by default, and gated by MOC discipline — dry-run, one-shot approval, undo capture, hash-chained audit.

Proving the analysis needs no model

The analysis layers cannot reach a language model. That is a guard, not a slogan: tests/test_brain_is_llm_free.py scans eight packages — brain, discovery, runtime, readiness, collect, knowledge, retain, connectors — for any import that could reach one, and an empty result is the guarantee. A model is used in exactly two places, and neither is load-bearing: rca_narrate rephrases a verdict that was already computed and already cited, and an agent front-end decides which tool to call. Remove both and the numbers are the same numbers.

That guard is static — it proves nothing can call a model. For a validation team the sentence they are asked to accept is the executed one, so it is executed:

iaiops verify determinism --out determinism-record.json

A pinned in-repo dataset goes through availability, production counts, the Six Big Losses, ISA-18.2 alarm load, control charts, the conservative baseline and the RCA copilot. Each result is canonically encoded and digested; the suite runs twice in this process and once in each of two fresh interpreters started at different PYTHONHASHSEED values — the arm that catches a set or dict iteration order reaching a result, which a single run never can. The socket API raises throughout, so a computation that reached for a device or a hostname fails here instead of quietly working on a machine that happened to be online. Afterwards the run is asked what it pulled in: a model library that was already loaded (an MCP server holds iaiops.core.llm for the opt-in narration tool) is recorded, not judged — only what the suite itself imported can condemn it.

The record separates result (identical every run — the part to sign) from context (when and where this run happened). Two good runs are not byte-identical records, and someone will diff them, so the halves are named rather than mixed.

This is the form the claim has to take to be usable: not "our model is accurate", which is not evidence in a GxP context, but a test case someone can write into an IQ/OQ protocol — remove the model, block the network, re-run the standard dataset, compare the hash — execute, and sign. verify_determinism is the same check from the MCP side; iaiops verify suite lists what it covers without running it.

How far it's actually been verified

Short version: verified against real protocol libraries, containers and in-process servers — not yet against real plant gear. We grade evidence rather than saying "tested", because a real container round-trip and a synthetic fixture are not the same claim.

Rung Who judges our frames Protocols at this rung today
2a — real wire to a third-party server somebody else's implementation of the spec OPC-UA (Microsoft opc-plc; certificate trust enforced both ways) · Modbus TCP (pymodbus) · Modbus RTU (pymodbus over a socat PTY) · MQTT / Sparkplug B (a real mosquitto broker) · BACnet/IP (bacpypes3, two IPs on one subnet) · MTConnect (the Institute's own cppagent) · SECS/GEM (secsgem equipment side) · EtherNet/IP (identification)
2b — real wire to a server we wrote from the spec the third-party client parses our frames S7comm (pyS7) · Mitsubishi MC (pymcprotocol) · EtherNet/IP (tag layer — pycomm3, all three driver routes) · PROFINET-DCP
2c — real wire, but both ends are ours nobody independent Omron FINS · IO-Link · HART-IP (codec itself at rung 1, against hart-protocol) · serial ASCII (our own weighing simulator)
mock only — protocol logic exercised, nothing on the wire — EtherCAT · BAS (Metasys / Niagara) · Ignition gateway
3 — real physical / vendor device the device zero, for every protocol

Each row's detail — and, per protocol, what is still not covered — is in docs/VERIFICATION-RECORD.md. That file is the record; this table is its summary, and a test fails if the two disagree.

Per-protocol evidence — including what each test does not cover — is in docs/VERIFICATION-RECORD.md, one row per protocol, naming the test behind each claim. Every 待核实 is hardware-gated, not forgotten — each one names the equipment that would settle it.

🧪 测试与共创 / Beta testing & co-creation

我们在找现场测试伙伴。 软件里能验证的我们都验证了(真实 in-process 服务器、真实协议库、Docker 容器 loopback)——剩下的 待核实 清单只有真设备能回答:物理 Modbus-RTU(RS-485)、EtherCAT 从站、HART 网关、在线 BACnet 楼宇设备、在线 Metasys/Niagara BAS 控制器、在线 Ignition 网关、国产 PLC(汇川/信捷)、真机 PLCnext、真实变电站 RTU/IED、欧姆龙 FINS 真机、IO-Link 主站。如果你是 OT 工程师、系统集成商或工厂团队,手上有任何这类设备:装上 iaiops,对你的设备跑一遍 iaiops doctor,把结果告诉我们。经你验证的设备会署名写进支持矩阵;现场反馈的问题我们优先分诊;功能可以通过 GitHub Issues/Discussions 直接共创。

We're looking for field-testing partners. Everything software-verifiable has been verified; what's left on the honest 待核实 list only real equipment can answer — physical Modbus-RTU (RS-485), EtherCAT slaves, HART gateways, live BACnet HVAC, live Metasys/Niagara BAS controllers, live Ignition gateway, domestic PLCs (Inovance/Xinje), live PLCnext, substation RTUs/IEDs, live Omron FINS PLCs, IO-Link masters. If you're an OT engineer, integrator, or factory team with access to any of these: install iaiops, run iaiops doctor against your gear, and tell us what happened. Verified-equipment reports get credited in the support matrix, field-reported issues get fast triage, and features are co-designed in the open via GitHub Issues/Discussions.

👉 参与入口 | Start here: open an issue with the protocol and device model in the title, or email zhouwei008@gmail.com. Either reaches a person, and a report gets answered against the current release.


Consolidated capability matrix

Protocol Tool Operation R/W risk_tier Returns (key fields)
OPC-UA opcua_server_info server status R low state, product_name, namespaces
OPC-UA opcua_browse browse node tree R low [{node_id, browse_name, depth}]
OPC-UA opcua_read_node read one node R low value, datatype, source_timestamp, good
OPC-UA opcua_read_many batch read R low [{node_id, value, ...}]
OPC-UA opcua_subscribe_sample bounded sample R low {collected, samples[]}
OPC-UA opcua_read_alarms alarm surfacing R low {active_alarms[], active_count}
OPC-UA opcua_read_history Historical Access (HDA) R low {supported, count, values[]}
OPC-UA opcua_diagnose_connection connection triage R low {verdict, checks[]}
OPC-UA opcua_discover_tags tag auto-discovery → semantic asset model R low {tag_count, assets[], naming_report}
OPC-UA opcua_health_summary threshold classify (was health_summary¹) R low {overall, counts, offenders[]}
OPC-UA opcua_anomaly_scan stddev outliers (was anomaly_scan¹) R low {mean, stddev, outliers[]}
Modbus modbus_read_holding FC03 R low {raw_registers, decoded[]}
Modbus modbus_read_input FC04 R low {raw_registers, decoded[]}
Modbus modbus_read_coils FC01 R low {bits[]}
Modbus modbus_read_discrete FC02 R low {bits[]}
Modbus modbus_detect_byte_order byte/word-order auto-detect R low {best_order, candidates[]}
Modbus modbus_list_templates vendor register templates R low {templates[]}
Modbus modbus_apply_template decode block via template R low {values:{name: engineering_value}}
Modbus modbus_health_summary threshold classify R low {overall, counts, offenders[]}
S7comm s7_cpu_info CPU id + run/stop R low {cpu_status, cpu_info}
S7comm s7_read_area read DB/M/I/Q R low {items:[{address, value}]}
S7comm s7_read_db read data block R low {items:[{address, value}]}
S7comm s7_read_many batch addresses R low {items:[{address, value}]}
S7comm s7_write_db write data block W high/MOC {before, written, _undo_id}
Mitsubishi MC mc_cpu_status CPU type R low {cpu_type, cpu_code}
Mitsubishi MC mc_read_words word devices R low {words[]}
Mitsubishi MC mc_read_bits bit devices R low {bits[]}
Mitsubishi MC mc_read_many random read R low {words[], dwords[]}
Mitsubishi MC mc_write_words write words W high/MOC {before, written, _undo_id}
Omron FINS fins_cpu_info controller data read (0501) R low {controller_model, controller_version}
Omron FINS fins_cpu_status controller status (0601) R low {run_mode, status}
Omron FINS fins_read_words memory-area word read (DM/CIO/W/H/A/EM) R low {words[]}
Omron FINS fins_read_bits memory-area bit read R low {bits[]}
Omron FINS fins_read_many batch reads R low {items[]}
Omron FINS fins_write_words memory-area write W high/MOC {before, written, _undo_id}
MTConnect mtconnect_probe device model R low {devices:[{components:[{data_items}]}]}
MTConnect mtconnect_current latest values R low {observations[]}
MTConnect mtconnect_sample bounded stream R low {observations[]}
MTConnect mtconnect_assets assets R low {assets[]}
MTConnect mtconnect_oee_snapshot OEE inputs R low {availability, execution, verdict}
MQTT/Sparkplug mqtt_read_topic bounded read R low {messages:[{topic, payload}]}
MQTT/Sparkplug sparkplug_subscribe_sample bounded SpB sample (full decode) R low {samples:[{sparkplug, payload:{metrics[]}}], seq_gap_count}
MQTT/Sparkplug sparkplug_decode_payload decode raw SpB payload R low {metrics:[{name, alias, datatype, value, is_historical}]}
MQTT/Sparkplug sparkplug_node_list node discovery + state R low {nodes:[{group_id, edge_node_id, online, devices}], primary_hosts[]}
MQTT/Sparkplug uns_browse topic-tree browse R low {topics[], tree{}}
MQTT/Sparkplug uns_topic_audit UNS naming + sprawl governance R low {verdict, sprawl_findings, findings{casing_collisions[], scattered_leaves[], …}}
MQTT/Sparkplug uns_schema_drift Sparkplug schema-drift (baseline vs current) R low {verdict (none/additive/breaking), node_changes[]}
MQTT/Sparkplug uns_live_audit live UNS audit (bounded broker sample) R low {verdict, findings{}}
MQTT/Sparkplug sparkplug_live_schema live NBIRTH schema snapshot R low {nodes[], metrics[]}
MQTT/Sparkplug sparkplug_point_draft observed BIRTH metrics → unconfirmed point refs R low {candidate_tags[], complete:false}
MQTT/Sparkplug uns_live_drift live drift vs stored baseline R low {verdict, node_changes[]}
MQTT/Sparkplug mqtt_publish publish/command W high/MOC {published_bytes, applied}
EtherNet/IP eip_controller_info Logix controller id R low {controller:{vendor, product_name, revision, serial}}
EtherNet/IP eip_list_tags tag discovery R low {tag_count, tags:[{name, data_type, structure}]}
EtherNet/IP eip_read_tag read one tag/array R low {tag, value, type, good}
EtherNet/IP eip_read_many batch read R low {items:[{tag, value, type}]}
EtherNet/IP eip_write_tag write tag W high/MOC {before, written, _undo_id}
Diagnostics diagnose_dataflow localize no-data R low {verdict, diagnosis, hops[]}
Diagnostics alarm_bad_actors ISA-18.2 flood R low {flood_verdict, top_offenders[]}
Diagnostics tag_health offender ranking R low {overall, offenders[]}
Diagnostics historian_health gap/flatline R low {verdict, gaps[]}
Diagnostics subscription_health sequenced-feed loss/reorder/overload R low {verdict, missed_count, overloaded_channels[]}
Diagnostics downtime_root_cause AI downtime RCA copilot (cited, advisory) R low {verdict, primary_cause, hypotheses:[{cause, confidence, evidence[]}]}
Diagnostics downtime_root_cause_live RCA copilot that gathers its own live evidence R low {…downtime_root_cause…, collected_evidence}
Diagnostics learn_cause_weights learn per-site RCA cause weights from labeled incidents R low {cause_weights{}, rationale}
Diagnostics data_quality_scorecard fleet data-trust rollup R low {fleet_score, fleet_status, issue_breakdown, worst_tags[], endpoints[]}
Diagnostics data_quality_fleet_rollup cross-endpoint fleet view R low {fleet_score, endpoints[]}
Diagnostics heartbeat_health heartbeat/watchdog liveness R low {alive, distinct_transitions, longest_stall_s, reason}
Alarm (ISA-18.2) alarm_flood_analysis flood episodes / chattering / stale / summary R low {episodes[], chattering[], stale[], summary{}}
Alarm (ISA-18.2) alarm_rationalization_worksheet CSV-exportable rationalization rows R low {rows[], csv_path?}
Baseline baseline_learn conservative change-log baseline (refuses thin history) R low {band{p1,p99,median,mad} | insufficient_data}
Baseline baseline_check silent-by-default violation check R low {status, violations[] (cited)}
Baseline baseline_record_change record operator change (restarts learning) R low {recorded, change_point}
Baseline baseline_status no_baseline / learning / ok / violation R low {status, window}
Historian historian_query read history back out of sqlite/TDengine/IoTDB R low {rows[], truncated}
Historian historian_coverage per-tag row counts + first/last ts R low {tags:[{tag, rows, first, last}]}
PLC program plc_program_outline structure of exported ST/AWL/L5X program R low {blocks[], call_graph, timers[]}
PLC program plc_program_xref symbol/address cross-reference (cited lines) R low {sites:[{kind, source_file, line, quote}]}
PLC program plc_program_xref_config program addresses ↔ one endpoint's configured points, exact address only (never by name); optional live read of matched points R low {comparable, matched, in_export_not_configured, configured_not_in_export, unmatchable}
PLC program plc_program_section one named block's source (≤200 lines) R low {text, source_file}
Export export_data export local store → CSV/SQLite/Parquet R low {path, row_count, preview[]}
Analytics oee_compute OEE = A×P×Q R low {availability, performance, quality, oee, oee_pct}
Analytics downtime_events stoppage detect + categorize R low {event_count, total_downtime_s, by_category, events[]}
Analytics oee_multidim OEE machine×part×shift R low {matrix[], worst_performers[], mean_oee}
Analytics asset_inventory active fingerprint R low {assets:[{protocol, vendor, model, firmware, reachable}]}
Analytics cross_protocol_asset_model merge discovered tags into one asset model R low {assets[], tag_count}
Analytics adopt_alias_map / diff_alias_map tag alias-map adopt/diff R low {aliases{}, changes[]}
Analytics monitor_changes bounded change-of-value R low {change_count, changes:[{value, previous, wall_clock}]}
EtherCAT ethercat_master_state master/WKC + slave count R low {master_state, expected_working_counter, slaves_found, slaves_expected}
EtherCAT ethercat_slaves bus scan R low {slave_count, slaves:[{index, name, vendor_id, product_code, state}]}
EtherCAT ethercat_slave_info slave detail R low {sync_managers[], fmmus[], object_dictionary[], input_bytes}
EtherCAT ethercat_read_sdo CoE SDO upload R low {index, byte_length, hex, as_uint}
EtherCAT ethercat_read_pdo input PDO snapshot R low {working_counter, input_hex, input_byte_length}
EtherCAT ethercat_write_sdo CoE SDO download W high/MOC {before, written, applied}
EtherCAT ethercat_set_state AL-state transition W high/MOC {before, requested, reached, applied}
PROFINET profinet_discover DCP IdentifyAll (segment-wide) R low {station_count, stations:[{name_of_station, mac, ip, vendor_id, device_roles[]}]}
PROFINET profinet_identify_station identify by name-of-station R low {found, name_of_station, mac, ip, device_family}
PROFINET profinet_station_params targeted DCP Get (by MAC) R low {found, name_of_station, ip, netmask, gateway}
PROFINET profinet_asset_inventory DCP asset register R low {asset_count, io_controller_count, assets[]}
PROFINET profinet_dcp_set DCP Set (station name / IP suite) W high/MOC {before, applied, _undo_id}
SECS/GEM secsgem_equipment_status GEM link + identity (S1F1/F2) R low {communication_state, are_you_there}
SECS/GEM secsgem_list_status_variables SVID namelist (S1F11/F12) R low {count, status_variables[]}
SECS/GEM secsgem_read_status_variables SVID values (S1F3/F4) R low {svids, values[]}
SECS/GEM secsgem_list_equipment_constants ECID namelist (S2F29/F30) R low {count, equipment_constants[]}
SECS/GEM secsgem_read_equipment_constants ECID values (S2F13/F14) R low {ecids, values[]}
SECS/GEM secsgem_list_alarms alarm list (S5F5/F6) R low {count, alarms[]}
SECS/GEM secsgem_list_process_programs PPID directory (S7F19/F20) R low {count, process_programs[]}
BACnet (building) bacnet_discover Who-Is device discovery R low {device_count, devices:[{device_id, address}]}
BACnet (building) bacnet_object_list a device's objects R low {object_count, objects:[{object_type, instance}]}
BACnet (building) bacnet_read_property one object property R low {object_type, instance, property, value}
BACnet (building) bacnet_read_points all present-values (HVAC snapshot) R low {point_count, points:[{object_type, instance, present_value}]}
BACnet (building) bacnet_cov_subscribe bounded COV capture (always unsubscribes) R low {notifications[], terminated_reason}
BACnet (building) bacnet_read_trend_log TrendLog readRange (bounded) R low {records:[{timestamp, value}]}
BACnet (building) bacnet_write_property present-value write (priority) W high/MOC {before, written, _undo_id}
HART-IP (process) hart_device_identity cmd 0 identity R low {manufacturer, device_type, revision}
HART-IP (process) hart_primary_variable cmd 1 PV R low {value, unit}
HART-IP (process) hart_dynamic_variables cmd 3 PV/SV/TV/QV + loop current R low {variables[], loop_current}
HART-IP (process) hart_burst_sample bounded burst-variable sampling R low {samples[]}
IO-Link iolink_master_info master identity R low {vendor, product, serial}
IO-Link iolink_ports ≤32-port sweep (mode/status/device id) R low {ports[]}
IO-Link iolink_device_info per-port device identity R low {vendor_id, device_id, product_name}
IO-Link iolink_read_pdin process-data-in (raw hex + bytes) R low {hex, bytes[]}
IO-Link iolink_read_isdu ISDU acyclic parameter read R low {index, subindex, value}
IO-Link iolink_scan master + all connected devices R low {master{}, devices[]}
Serial ASCII serial_sniff raw lines from a serial instrument (sends nothing) R low {endpoint, seconds, lines[], note}
Sensor (IAIOPS_MCP=sensor) sensor_import_iodd draft a profile from an IODD (待核实; returns text, writes nothing; reads only under the agent read roots — see Safety & governance) R low {draft, profile_id, device_name, notes[]}
Sensor (IAIOPS_MCP=sensor) sensor_profile_check validate a profile file, list its channels (reads only under the agent read roots) R low {id, protocol, verified, channels:[{channel, layout, unit, signal, band}]}
Sensor (IAIOPS_MCP=sensor) sensor_read_channel read one point once; reachable / decodable reported separately R low {levels:{reachable, decodable}, value?, unit?, band?, verified?}
Sensor (IAIOPS_MCP=sensor) sensor_profile_list list the shipped profile library (every entry 待核实 unless it carries provenance) R low {profiles:[{id, protocol, verified, caveat}]}
Sensor (IAIOPS_MCP=sensor) sensor_profile_show one library profile: summary + YAML text (writes nothing) R low {summary, yaml, next}
BAS (Metasys/Niagara) bas_point_list supervisory point directory R low {point_count, points:[{id, name, type}]}
BAS (Metasys/Niagara) bas_point_read read one supervisory point R low {point, value, unit, status}
BAS (Metasys/Niagara) bas_alarm_list active controller alarms R low {alarm_count, alarms:[{id, priority, state}]}
BAS (Metasys/Niagara) bas_trend_read trend/history samples (bounded) R low {records:[{timestamp, value}]}
BAS (Metasys/Niagara) bas_command supervisory command (default-OFF; life-safety object denylist refuses fire/smoke/egress/pressurization before any I/O) W high/MOC {before, written, _undo_id}
Ignition ignition_gateway_status Gateway + module health R low {state, version, modules:[{name, state}]}
Ignition ignition_tag_browse tag-tree browse R low {tags[], tree{}}
Ignition ignition_tag_read current tag values R low {values:[{path, value, quality, timestamp}]}
Ignition ignition_alarm_status active alarms R low {alarm_count, alarms:[{path, priority, state}]}
Ignition ignition_tag_history tag-history query (bounded) R low {rows:[{path, timestamp, value}]}
信创 / compliance compliance_mapping 《工控网络安全防护指南》↔ iaiops R low {pillars[], status_summary, controls:[{pillar, status, gap}]}
信创 / compliance compliance_frameworks 等保 2.0 + IEC 62443 FR1–6 + GxP crosswalk; framework="nis2"|"cra" = NIS2 Art. 21 / CRA Annex I item by item R low {crosswalk[]} | {items:[{ref, coverage, mechanisms, gap}]}
信创 / compliance compliance_dengbao_levels 等保 二级 baseline vs 三级 增量 R low {pillars:[{l2, l3_delta, status}]}
信创 / compliance compliance_report deliverable compliance report (md/html); framework="nis2"|"cra"|"eu" for the English EU self-assessment R low {markdown | out_path}
信创 / compliance compliance_evidence_bundle audit-evidence zip (hash-chain verified) R low {bundle_path, manifest}
信创 / historian historian_push push telemetry to sqlite/TDengine/IoTDB R(→historian) low {sink, received, written, skipped_non_numeric}
Self protocols_supported capability map R low {protocols[], diagnostics[], analytics[]}

(The energy protocols — IEC-104 / DNP3 / IEC-61850 — moved to iaiops-energy in 0.8.0; their tool matrix lives in that repo.)

206 governed tools = 189 read + 4 that change nothing on a device but send data off-box (stream_publish, stream_publish_event, uns_publish, rca_narrate) + 10 MOC-gated device writes + historian_push (a write, to a historian rather than to a device: [WRITE][risk=low]) + the 2 deprecated aliases below. The device writes are (s7_write_db, mc_write_words, fins_write_words, mqtt_publish, eip_write_tag, ethercat_write_sdo, ethercat_set_state, profinet_dcp_set, bacnet_write_property, bas_command). The read side now includes two vendor-REST read-only layers above the field protocols — a BAS controller layer (Metasys/Niagara, building edition) and an Ignition Gateway MES/SCADA layer (factory edition). ¹ The 2 deprecated aliases are the two deprecated brain aliases health_summary / anomaly_scan, renamed to opcua_health_summary / opcua_anomaly_scan in 0.10.0 — the deprecated aliases are still registered and will be removed in a future release (target: 1.0.0). Read-only per-edition tools load ONLY under their edition (see per-edition tool modules below), so a bare protocol / single-edition surface is smaller than this line-wide total. The table above is representative, not exhaustive; run protocols_supported() (or iaiops protocols) for the live map.


Per-protocol reference

OPC-UA
  • Versions/variants: binary opc.tcp:// via asyncua (sync facade). Security: anonymous + username/password, plus application-certificate message security (Sign / SignAndEncrypt) — set client_cert + client_key (+ optional server_cert) and the client opens a signed/encrypted secure channel (no cert ⇒ the anonymous / username path is unchanged). Validated end-to-end against an in-process asyncua server (tests/test_opcua_security.py) for Basic256Sha256 in both Sign and SignAndEncrypt modes: server_cert pinning and client-side server-cert auto-discovery are exercised, and the test asserts the negotiated policy URI + message-security mode on the live encrypted channel (plus a negative test that anonymous is refused by a secure-only server).
  • Connection params: endpoint_url, username (password encrypted), security_mode, security_policy; for cert security client_cert / client_key / optional server_cert (PEM or DER paths; aliases certfile / keyfile).
  • Alarms & Conditions: opcua_alarm_events — bounded event subscription + ConditionRefresh, events carry the server's own timestamps (verified against an in-process asyncua server; third-party A&C servers 待核实). Untimed fallback: opcua_read_alarms browses alarm-like boolean nodes.
  • Not supported / planned (待核实): cert-security interop with third-party / vendor servers (KEPServerEX / Prosys / Siemens / real PLCs), the other policies (Aes128Sha256RsaOaep / Aes256Sha256RsaPss / Basic128Rsa15 / Basic256), strict server-side certificate-trust enforcement, and cert-based user identity (X509 identity token, distinct from channel security).
Modbus-TCP / Modbus-RTU
  • Versions/variants: Modbus-TCP and Modbus-RTU (serial RS-485/232) via pymodbus (+ pyserial). Read function codes FC01 (coils), FC02 (discrete), FC03 (holding), FC04 (input). Write FCs (FC05/06/15/16) = not implemented (read-only).
  • Connection params: TCP — host, port (502), unit_id. RTU — transport: rtu, serial_port (e.g. /dev/ttyUSB0), baudrate, unit_id. Registers are untyped 16-bit words → decode hint (uint16/int16/uint32/int32/float32/raw); modbus_detect_byte_order auto-detects the byte/word order (AB/BA · ABCD/DCBA/BADC/CDAB) from hint values — pure logic, no extra device load.
  • Typed points for collection (HLD §16): a collected/monitored ref can name its table, type, word order and scale — ir:0:float32:CDAB, hr:12:int16*0.1 (grammar <hr|ir>:<addr>[:<type>[:<order>]][*<scale>]; a 32-bit type must state its order). With sensor_profile: <file> on the endpoint, ch:<name> reads a channel of that profile (sentinels → gaps, declared range enforced). A bare address keeps its old meaning (one holding register, uint16) and readiness reports it as untyped. Switching sensors (NPN / PNP / dry contact) on a DI module read as di:<addr>:<high|low> (FC02) or co:<addr>:<high|low> (FC01): the active level is required (a normally-closed switch reads 0 when actuated), the value is 1 = actuated, and readiness reports a count_source gap when a switching point is declared as the production counter (polling misses short pulses) — checked on Modbus refs only; PLC bits are not yet checked. A shipped profile library (iaiops sensor list | show, MCP sensor_profile_list | show) holds community register maps for common energy meters and PV inverters, each derived from the Modbus template of the same device and carrying its caveat — every entry 待核实; CI checks each entry against its template channel by channel, in both directions. Copy one (show <id> --out <file>), check a reading against the device's display, then bind the copy.
  • Vendor register templates (modbus_list_templates / modbus_apply_template): named register maps decoding a block into engineering values — energy meters (Eastron SDM630, Schneider PM5xxx, Carlo Gavazzi EM24), PV inverters (Huawei SUN2000, Growatt), Phoenix PLCnext process data, and water-industry templates (E+H Promag, Hach SC controller, generic dosing pump). Each template carries an explicit 待核实 caveat — no invented "verified" addresses.
  • Coverage: many domestic 国产 PLCs (汇川 Inovance / 信捷 Xinje / 和利时 Hollysys / 台达 Delta) and any Modbus vendor. RTU framing is live-verified over a real serial link (socat PTY + pymodbus RTU server); specific physical RS-485 devices stay 待核实.
S7comm (Siemens + 仿西门子 国产)
  • Versions/variants: pyS7 (pure-Python, ISO-on-TCP / RFC1006 — no native libsnap7). S7-300/400/1200/1500 and compatible clones. Memory areas DB / M (merker) / I / Q. No protocol auth (CPU gates via "Permit access with PUT/GET").
  • Connection params: host, port (102), rack, slot (0/1 for 1200/1500; 0/2 common for 300/400).
  • Write: s7_write_db = high risk_tier, MOC, dry-run default, captures BEFORE value + undo.
  • Not supported / planned: optimized/symbolic DB access on 1500 with "optimized block access" can require absolute-addressing config on the CPU.
Mitsubishi MC
  • Versions/variants: pymcprotocol — MC 3E frame (binary) only. 1E / 4E frames = not supported. PLC types Q / L / QnA / iQ-R / iQ-L. Devices: D/W/R (word), M/X/Y/B (bit).
  • Connection params: host, port (5007 default; set to the module's open MC port), plctype.
  • Write: mc_write_words = high/MOC/dry-run default, captures BEFORE + undo.
Omron FINS (CS/CJ/CP/NX-via-FINS)
  • Versions/variants: in-repo, stdlib-only FINS client (no third-party dependency — the iaiops[fins] extra pins nothing): 10-byte FINS header framing, FINS/UDP (default port 9600) and FINS/TCP (node-address handshake per Omron W342), SID matching, bounded response parsing, end-code table per W227/W342. Commands: 0101 memory-area read (words/bits over DM/CIO/W/H/A/EM), 0102 write, 0501 controller data read, 0601 controller status.
  • Connection params: host, port (9600), transport (udp default / tcp), FINS network/node/unit addressing.
  • Write: fins_write_words = high/MOC/dry-run default, captures BEFORE + undo; CLI double-confirm on --apply.
  • Validation: verified against an in-repo mock FINS UDP/TCP responder (tests/test_fins.py); live Omron PLC behaviour and banked-EM access stay 待核实.
IO-Link (master JSON integration — read-only)
  • Versions/variants: sensor-level visibility via the IO-Link master's HTTP/JSON interface (IO-Link consortium "JSON Integration"), both dialects selectable per endpoint via flavor: — iotcore (ifm IoT-Core POST envelope, default) and rest (plain-REST GET, Balluff/Turck-style). Reads: master identity, bounded ≤32-port sweep, per-port device identity, process-data-in (raw hex + bytes), ISDU acyclic parameter read. NO write tools. Bounded/size-capped HTTP (256 KiB response cap), schema-checked JSON with teaching errors. Reuses the MTConnect HTTP pin (iaiops[iolink] → requests).
  • Connection params: master host/URL, flavor, timeout_s. protocol: iolink.
  • Collection (HLD §16): port_profiles: {<port>: <profile.yaml>} binds a sensor profile per port; port<N>/<channel> refs are then collectable (collect, monitor). A port without a profile is not decoded — refused, never guessed. If the profile carries match: {vendor_id, device_id}, the device on the port is checked before decoding (cached 5 s per master and port, dropped on any failed read). With pd_bits, a process-data image of another length is refused. iaiops sensor import-iodd <iodd.xml> drafts a profile from the vendor's IODD (verified: 待核实, unit codes left unmapped, unrepresentable items listed); iaiops sensor check validates one.
  • Validation: in-process mock master in both flavors (tests/test_iolink.py); profile decoding against a hand-written IODD-shaped fixture (tests/fixtures/iodd/). Live master datapoint paths, identity encodings and real vendor IODDs stay 待核实.
Serial ASCII instruments (scales, analysers, barcode readers, legacy meters — read-only)
  • Versions/variants: instruments that send one text line per reading over RS-232 / RS-485 / RS-422 / USB virtual COM (pyserial>=3.5, extra iaiops[serial], included in iaiops[sensor]) or through a serial device server's raw TCP socket. Decoding is a sensor profile (protocol: serial): framing (terminator, encoding, max line), mode: listen | poll (+ the ONE query poll may send), and per channel a regex that must match the whole line with a value group, status codes (ok / named invalid → gaps) and the unit fixed and/or from the line.
  • Safety rules: the port is opened exclusively — a port another program holds is refused, never taken (an advisory lock: a program that opened it without locking cannot be detected, 待核实 per OS). Poll needs bus: dedicated on the endpoint (shared = an RS-485 bus that already has a master: listen only); tare / zero / calibrate are not reads and do not belong in query. Listen needs stale_after_s (no line within it = a gap, never the last value). Collection requires a fixed unit per channel.
  • Tools: serial_sniff / iaiops serial sniff (raw lines, sends nothing); decoded reads via sensor_read_channel / iaiops sensor read; collection via iaiops collect run.
  • Validation: a pty pair through the real pyserial path, a local TCP device-server path, and a lab LAN walkthrough against our own weighing simulator (rung 2c — no third-party instrument). No serial profile ships — you write one per instrument (iaiops serial sniff shows the raw lines), and its line format stays 待核实 until checked against the real device.
HART-IP (process instrumentation — read-only)
  • Versions/variants: HART universal commands over HART-IP UDP (default, port 5094) or TCP (transport: tcp, length-delimited framing) via an in-tree transport; the HART command codec is verified vs hart-protocol. Tools: hart_device_identity (cmd 0), hart_primary_variable (cmd 1), hart_dynamic_variables (cmd 3, PV/SV/TV/QV + loop current), hart_burst_sample (bounded sampling of burst-published variables). No write / device-specific commands exposed (OT-dangerous on live instruments).
  • Connection params: host (HART-IP server/gateway), port (5094), transport (udp default / tcp).
  • Validation: TCP transport loopback-verified (in-process HART-IP server, real long-frame ACK through the real codec path); live gateway behaviour and a true unsolicited burst subscription stay 待核实.
MTConnect (ALL CNC machine tools)
  • Versions/variants: agent REST + XML (requests + xml.etree), namespace-agnostic (parses MTConnect 1.x Devices/Streams/Assets schemas). Endpoints: /probe, /current, /sample, /assets. Read-only by specification. XML parsing is hardened (DTD/entity declarations rejected — XXE/billion-laughs defense).
  • Connection params: agent_url (e.g. http://host:5000).
  • Not supported / planned: MTConnect streaming (long-poll interval=); only bounded count= samples.
MQTT / Sparkplug B / UNS
  • Versions/variants: paho-mqtt — MQTT 3.1.1 & 5. Sparkplug B topic convention spBv1.0/{group}/{type}/{edge}/[device] (NBIRTH/DBIRTH/NDATA/DDATA/NDEATH/DDEATH/STATE). TLS + username/password supported.
  • Full Sparkplug B decode (no optional extra): payloads are protobuf-decoded with a vendored, byte-for-byte copy of the official Eclipse Tahu sparkplug_b.proto generated module (depends only on protobuf). Per metric you get name, alias (resolved to its name via the BIRTH model), datatype (Int8…Int64/UInt…/Float/Double/Boolean/String/DateTime/Text/UUID/DataSet/Bytes/File/Template/PropertySet…), value, timestamp, and the is_historical / is_null flags. A birth/death + seq model tracks node/device online state (NBIRTH/DBIRTH ↔ NDEATH/DDEATH), builds the alias→name map from BIRTH, applies NDATA/DDATA by alias, and flags seq gaps / out-of-order. Primary-host awareness: STATE/<host_id> topics surface in sparkplug_node_list. sparkplug_decode_payload decodes a single raw payload (base64/hex) offline.
  • A data SOURCE, not just a bus (new): MQTT/Sparkplug is collectable — iaiops collect run holds ONE subscription open for the run and samples from its last-value cache, so a plant whose data is already unified into a UNS can be tapped without touching a PLC. Refusals are the feature. MQTT is pushed, and the obvious cache answers with the last value forever after a publisher dies — availability then reads 100% on a stopped line, in every subscriber at once. So a point is a reading only when it has been seen at all (never-published is not zero), is fresher than stale_after_s, and — for Sparkplug — its node has not sent NDEATH/DDEATH. Anything else raises OTNoReadingError, which the collector records as a gap (collection was blind), never as downtime.
  • stale_after_s is REQUIRED to collect, and deliberately has no default: a value that stopped updating and one that is simply constant are identical on the wire, so only the site knows how often a point is published. Guessing it here would put a guess underneath every availability figure. Same discipline as running_when on a run_state tag.
  • The two guarantees are not equal, and the endpoint is told which it has: Sparkplug gives staleness and death (the broker publishes the node's Last Will); plain MQTT has no death signal at all, so only staleness is available there and a quiet topic is indistinguishable from a dead publisher.
  • Refs: a plain-MQTT ref is the topic itself; a Sparkplug ref is group/edge[/device]:metric — exactly the node id mqtt live-schema reports, so its output is usable as config refs without translation. Payloads decode as a bare scalar or a {"value": …} / {"v": …} JSON envelope; an unknown envelope is not guessed at by picking its only number.
  • Connection params: host/broker, port (1883 / 8883 TLS), topic, use_tls, username (password encrypted), stale_after_s (required for collection).
  • Validation: verified end-to-end against a real eclipse-mosquitto:2 broker through the full paho loop (tests/test_uns_tap_live.py, opt-in) — publish → read → publisher stops → the run records a gap instead of repeating the cache. Also exercised across a real network on three separate hosts (broker, edge node, reader) against a spec-correct Sparkplug node — alias-only NDATA, periodic re-BIRTH, and a genuine broker-issued Last Will after the publisher was kill -9'd on another machine (refusal in ~2s with stale_after_s deliberately set to 60, so only the death signal could have caused it). 待核实: the edge node is still our own implementation, not a commercial EoN (Ignition / Litmus / HighByte), and not a commercial broker (HiveMQ / EMQX).
  • Command: mqtt_publish = high/MOC/dry-run default. A transient publish has no automatic inverse (delivered is delivered); a retained one overwrites durable broker state, so it captures the prior retained payload and records an inverse.
EtherNet/IP (Rockwell / Allen-Bradley)
  • Supported: ControlLogix / CompactLogix (and GuardLogix) via CIP / EtherNet-IP using pycomm3 (pure-Python — no native deps). Tag-based, symbolic access: read/write tags by name (Conveyor.Speed, Array[3], Program:Main.X) and discover the controller's tag list at runtime (eip_list_tags, the headline feature). eip_controller_info reads the controller identity.
  • Connection params: host, slot (0 for CompactLogix; the CPU slot for a ControlLogix chassis), port (44818). protocol: ethernetip (alias eip).
  • Write: eip_write_tag = high risk_tier, MOC, dry-run default, captures BEFORE value + undo.
  • Also supported (mocked drivers only — real hardware 待核实): PLC-5 / SLC-500 / MicroLogix via PCCC data-table addressing, and Micro800.
EtherCAT (pysoem / SOEM fieldbus master)
  • Supported: a real EtherCAT master via pysoem (the Python binding for the SOEM C stack). CoE SDO read (ethercat_read_sdo, acyclic mailbox upload) + SDO write (ethercat_write_sdo, download), input PDO read (ethercat_read_pdo, one bounded cyclic snapshot), bus scan / slave enumeration (ethercat_slaves, ethercat_slave_info — identity, SM/FMMU mapping, object-dictionary summary), master/working-counter state (ethercat_master_state), and AL-state transitions INIT↔PREOP↔SAFEOP↔OP (ethercat_set_state).

  • HARD REQUIREMENTS (no way around them): Linux, root or CAP_NET_RAW, a dedicated NIC cabled to the bus, and real EtherCAT slave hardware. pysoem is an OPTIONAL extra: pip install iaiops[ethercat] — the base package installs and imports without it, and every EtherCAT tool then degrades to a teaching error (never crashes, never imports pysoem at module load).

  • NOT supported: no software simulator exists (unlike OPC-UA / Modbus) — EtherCAT is hardware-only and not testable in mock-only CI; macOS is unsupported. EoE / FoE / SoE mailbox protocols and full PDO-mapping decode/expansion = roadmap.

  • Connection params: nic (the dedicated interface name, e.g. eth1; alias interface), optional expected_slaves (a sanity check vs the bus scan). protocol: ethercat.

  • Operations matrix:

    Tool Op R/W risk Capture/notes
    ethercat_master_state master + WKC state, slave count R low expected vs found
    ethercat_slaves bus scan / enumerate R low index/vendor/product/rev/addr/AL-state
    ethercat_slave_info one-slave detail R low SM/FMMU + OD summary
    ethercat_read_sdo CoE SDO upload R low hex + uint interpretation
    ethercat_read_pdo input PDO snapshot R low single cycle, never loops
    ethercat_write_sdo CoE SDO download W high/MOC before-value (SDO read-back) + undo
    ethercat_set_state AL-state transition W high/MOC before-state + undo; can start/stop motion
  • Write/state safety: ethercat_write_sdo (hex little-endian bytes) and ethercat_set_state are high risk_tier, MOC, dry-run by default, capture the BEFORE value/state for undo, and need a CLI double-confirm. Changing EtherCAT state can START or STOP machine motion — treat with extreme care. 未经授权勿对生产控制系统写入.

PROFINET (DCP discovery / identify + gated DCP Set)
  • Supported: layer-2 PROFINET-DCP via pnio-dcp — profinet_discover (DCP IdentifyAll: one broadcast surfaces every station on the segment — name-of-station, MAC, IP, vendor/device id, role — closer to passive discovery than a per-device fingerprint), profinet_identify_station (by name-of-station), profinet_station_params (targeted DCP Get by MAC → name + IP suite), and profinet_asset_inventory (a register with IO-controller vs IO-device role decoding).
  • Write: profinet_dcp_set re-addresses one station (name-of-station and/or IP suite, by MAC) — high risk_tier, MOC, dry-run default, captures the BEFORE addressing + undo descriptor. Re-addressing a live station can disrupt its IO connection.
  • Scope (deliberate): no RT cyclic process data (that needs an IO-controller/IO-device stack and hard real-time — out of scope and unsafe to tap); the blink / factory-reset DCP services stay unexposed.
  • HARD REQUIREMENTS: raw-socket access (root / admin / CAP_NET_RAW) on the NIC on the PROFINET subnet. pnio-dcp is an OPTIONAL extra: pip install iaiops[profinet] — the base package installs/imports without it, and every tool then degrades to a teaching error.
  • Connection params: host — THIS machine's IP on the PROFINET subnet (the DCP broadcast goes out on it). protocol: profinet.
  • Preview caveat: validated against a mocked pnio-dcp DCP — not verified against live PROFINET devices yet.
Energy edition (electrical substation / utility telecontrol) → iaiops-energy

The energy vertical — IEC 60870-5-104 / DNP3 / IEC 61850 MMS read-only monitoring for substation RTUs/IEDs — moved to its own package in 0.8.0: iaiops-energy (pip install iaiops-energy), built on iaiops.core (shared governance / brain / runtime). Its protocol reference, support matrix, and validation status live in that repo.

Building edition (facility / HVAC / 厂务)

The building vertical adds BACnet/IP (ASHRAE 135) — the dominant building-automation protocol for HVAC, lighting, metering, and facility plant. Install with pip install iaiops[building] and expose with IAIOPS_MCP=building (bundle: bacnet + modbus + opcua + iolink).

  • BACnet/IP (BAC0 over bacpypes3): bacnet_discover (Who-Is device discovery), bacnet_object_list (a device's objects), bacnet_read_property (one object property), bacnet_read_points (present-value of all analog/binary/multistate points — the HVAC snapshot), bacnet_cov_subscribe (bounded change-of-value capture — capped by count AND wall-clock, always unsubscribes), bacnet_read_trend_log (TrendLog buffered records via one bounded readRange). Config: host = THIS machine's BACnet/IP interface (ip or ip/mask) / port (47808).
  • Write: bacnet_write_property (present-value at a BACnet priority 1..16, or relinquish) = high risk_tier, MOC, dry-run default, BEFORE-value read-back + undo. Overriding a live building-control point can move real HVAC/plant.
  • Validation: the read path is verified against a real bacpypes3 virtual BACnet/IP device through the actual async BAC0 stack (tests/test_bacnet_live.py); COV / trend-log / writes on live HVAC gear stay 待核实.
Water treatment edition (水处理)

IAIOPS_MCP=water (or iaiops-mcp-water, pip install iaiops[water]) exposes modbus + opcua + hart + the brain — the protocol set waterworks / wastewater plants actually run. Adds water-domain tag semantics (溶解氧 DO / ORP / 余氯 chlorine / 氨氮 ammonia / TSS/MLSS / 跨膜压差 TMP / UV / 加药 dosing / 曝气 aeration) and water-industry Modbus templates (E+H Promag, Hach SC controller, generic dosing pump — all with explicit 待核实 caveats).

Warehouse / intralogistics edition (仓储 / 物料搬运)

IAIOPS_MCP=warehouse (or iaiops-mcp-warehouse, pip install iaiops[warehouse]) exposes eip + profinet + modbus + opcua + sparkplug + the brain — conveyor & sorter drives over EtherNet/IP (Rockwell) and Profinet (Siemens), VFD / energy meters over Modbus (conveyor_vfd / agv_battery templates), WMS/WCS gateways over OPC-UA, and AMR/IoT telemetry over MQTT-Sparkplug. Edition tools (read-only, advisory): line_bottleneck (Theory-of-Constraints throughput bottleneck across stations) + sortation_health. PdM (pdm_forecast), downtime_triage and OEE are reused as-is.

Clinical-facility edition (医疗设施)

IAIOPS_MCP=clinical (or iaiops-mcp-clinical, pip install iaiops[clinical]) exposes bacnet + modbus + opcua + the brain — hospital facilities as a distinct patient-safety vertical over the building brain. Edition tools (read-only, advisory): isolation_room_check (负压/正压 isolation-room pressurization), medical_gas_check (medical-gas alarm-panel safety), or_environment_check (OR temperature / humidity / pressure envelope). BACnet BMS + Modbus gas-alarm panels + OPC-UA plant SCADA.

Pharmaceutical-manufacturing edition (制药)

IAIOPS_MCP=pharma (or iaiops-mcp-pharma, pip install iaiops[pharma]) exposes bacnet + modbus + hart + opcua + the brain. No new protocol — that is the point: no field protocol is specific to pharma. Cleanrooms run BACnet, purified-water systems run Modbus and HART, filling and lyophilization run S7, DCS and bioreactors run OPC-UA, and all of it was already here. What pharma needed was semantics: the water edition's indicators are municipal (DO, ORP, chlorine, turbidity) and the clinical edition grades one room's pressure, where Annex 1 inspects the cascade.

Edition tools (read-only, advisory): cleanroom_pressure_cascade (EU GMP Annex 1, door by door — adjacency is declared, never inferred from a room list), cleanroom_particle_check, pharma_water_check (USP <645> stage-1 procedure: the non-temperature-compensated reading, the measured temperature rounded down to the tabulated step, and exceeding stage 1 reported as proceed to Stage 2 rather than as a failure).

No compendial limit tables are shipped. The particle limits, the stage-1 conductivity table and the TOC limit belong to the site's qualified specification at its compendial revision. A transcription nobody in this repository can verify would end up deciding whether a batch environment passed — and the error that hurts is the flattering one, since a limit set too loose reads as "in specification". Limits are passed in and cited back; anything not declared is reported no_limit / not_graded and named, never counted as passing. Known gaps are listed in the edition's skill: no PI historian connector, S7 without hardware verification, and LIMS / QMS deliberately out of scope — they run REST and databases, not field protocols.

Renewables edition (光伏 / 风电)

IAIOPS_MCP=renewables (or iaiops-mcp-renewables, pip install iaiops[renewables]) exposes modbus + opcua + sparkplug + the brain — PV inverters (SUN2000 / Growatt templates) + wind-turbine controllers over Modbus, OPC-UA plant SCADA, and MQTT-Sparkplug telemetry. Edition tool (read-only, advisory): pv_performance (PV string performance vs expectation). Device-level monitoring + PdM via baseline / RCA.

Half-hourly electricity metering (supplier HH files — building & renewables editions)

A supplier's half-hourly (HH) electricity file, read and explained — the data every UK non-domestic meter produces as market-wide half-hourly settlement completes. No device is contacted; the input is a file. iaiops meter check FILE says what the file contains (wide layout: date + 46–50 half-hour columns; long layout: timestamp + kWh) and what was rejected; iaiops meter profile FILE [--hours 'mon-fri 08:00-18:00'] [--holiday YYYY-MM-DD] [--tariff tariff.yaml] [--report out.html] reports overnight base load, out-of-hours use against the declared operating hours, peak demand, complete-day working vs closed averages, load factor, a weekday × time heatmap and — with a tariff — cost by time band and an upper bound for moving use out of the dearest band. MCP (building + renewables editions): meter_hh_check, meter_load_profile (same engine; the HTML report is CLI-only). Demo: demo/metering/.

  • What it refuses to do: a blank cell is missing, never zero; totals are measured only, never scaled up over gaps; dates are UK day-first only (01/13/2026 is rejected, not reread); a file with no actual/estimated flag reports read type unknown, not "actual"; out-of-hours use above base load is labelled an indication, not a saving.
  • Clock days: the UK clock (GMT/BST) is computed from its rule — no tzdata needed — so the 46- and 50-period clock-change days are read correctly.
  • Not built in: DNO DUoS red/amber/green times (they vary by region — pass them in a tariff; demo/metering/tariff_example.yaml is illustrative only), VAT, CCL, kVA capacity and reactive charges (listed as excluded on every cost). Validation: synthetic files and the unit suite only — no real supplier file has been run through it yet (待核实).
PLCnext packaging edition (Phoenix Contact vPLC)

IAIOPS_MCP=plcnext (or iaiops-mcp-plcnext, pip install iaiops[plcnext]) exposes opcua + modbus + the brain — the Phoenix Contact PLCnext virtualized PLC reached over its built-in OPC-UA server (opc.tcp 4840, Arp.Plc.Eclr address space) + Modbus-TCP process-data server; no new connector. Route-verified in-process; live PLCnext hardware reads stay 待核实 (see How far it's actually been verified).

信创 / China entry (offline · 国产 TSDB · compliance)

For 自主可控 / 信创 deployments — see docs/CHINA.md for the full guide.

  • Air-gapped install: pure-Python core + per-protocol optional extras → install from a local wheelhouse with pip install --no-index --find-links ./wheelhouse "iaiops[...]"; secrets stay local (encrypted store), no cloud KMS.
  • National TSDB historian sink (historian_push, CLI iaiops historian push): write collected telemetry to TDengine (iaiops[tdengine]) or Apache IoTDB (iaiops[iotdb]) — domestic, controllable; we don't build our own store or bind InfluxDB. Data egress to the operator's own historian, not a control write.
  • Compliance mapping (compliance_mapping, CLI iaiops compliance): an honest 《工控系统网络安全防护指南》 ↔ iaiops self-assessment across 分区隔离 / 可审计 / 双向认证 / 最小权限 / 数据保护 / 自主可控, with per-control status (addressed / partial / 待核实) and the named gap.
  • 国产 PLC: 汇川 / 台达 / 信捷 over the existing Modbus-TCP / S7 connectors.
  • ⚠️ 待核实: 国产 OS (麒麟/统信) · 芯 (鲲鹏/海光) · PLC validation and the TSDB write paths are documented but not yet hardware-verified — see the validation matrix in docs/CHINA.md.
OEE / downtime analytics (cross-protocol, read-only)
  • oee_compute — OEE = Availability × Performance × Quality from production inputs (planned time, run time, ideal cycle, total/good counts). Each factor is reported raw + clamped to [0,1]; a capped performance >1.0 flags an optimistic ideal cycle.
  • downtime_events — auto-detects running→stopped transitions in a {timestamp, state} series and produces stoppage events with durations, categorized (changeover / material / mechanical / quality / break / unknown, by keyword heuristics or a {state: category} override).
  • oee_multidim — aggregates OEE across machine × part × shift (or any dimensions) from labelled records → the matrix + worst performers.
  • Operate over provided/collected inputs (fully testable without a plant). mtconnect_oee_snapshot surfaces the live MTConnect availability/execution inputs that feed these.
Active asset inventory / fingerprint (read-only)
  • asset_inventory — for each configured (or named) endpoint, actively connects with our own protocol client and reads its identity call (S7 s7_cpu_info, EtherNet/IP eip_controller_info, OPC-UA server build info, Modbus Device Identification FC43/0x2B, Mitsubishi CPU type, MTConnect device model), aggregating vendor / model / firmware / serial / reachable / last_seen into an asset register.
  • Honest scope (IEC 62443-flavored): this is ACTIVE fingerprinting via our client connections, NOT passive SPAN/tap discovery — it only finds devices we are configured to reach and adds light load to each. Passive, traffic-mirroring discovery is roadmap.
OPC-UA Historical Access (HDA)
  • opcua_read_history — reads stored historical values for a node over a [start,end] ISO-8601 window via the server's HistoryRead service (asyncua read_raw_history), bounded by max_points (≤2000). Returns {supported:false, note} gracefully when the server does not historize the node (no crash). Read-only.
Change-of-value (CoV) monitor
  • monitor_changes — bounded deadband report: polls a point and returns only the value CHANGES (with timestamps), not every sample. Works over OPC-UA / Modbus / S7 / Mitsubishi MC / EtherNet-IP. Never an infinite loop — hard-capped by both duration_s (≤120) and max_changes (≤500). Read-only.
Cross-protocol brain — 0.9/0.10 additions (all read-only)
  • Conservative baseline learning (baseline_learn/check/record_change/status, CLI iaiops baseline …) — a change-log baseline, explicitly NOT black-box anomaly detection: robust p1/p99 + median/MAD band over the local history, refuses thin history (<100 samples or <24h) with an explicit insufficient_data verdict, restarts at recorded operator changes, and is silent by default — a violation needs >3×MAD beyond the band AND ≥3 consecutive samples, and every violation cites its baseline window and offending samples.
  • Historian READ integration (historian_query / historian_coverage, CLI iaiops historian query|coverage) — query history back out of the sqlite/TDengine/IoTDB sinks; an optional per-site historian: config block lets the RCA copilot pull the 2h pre-incident window as one more cited evidence class (strictly additive — without the config, RCA output is byte-identical, test-proven).
  • Legacy PLC program explainer (plc_program_outline/xref/section, CLI iaiops program …) — structural extraction over exported program files (Siemens SCL/ST .scl/.st, AWL/STL .awl, Rockwell Studio 5000 .L5X — never a live PLC upload); every element carries source_file + line (rung for L5X) so the explaining agent must cite real locations. XXE-hardened, ≤5 MB, extension allowlist.
  • ISA-18.2 alarm flood deep-dive (alarm_flood_analysis / alarm_rationalization_worksheet, CLI iaiops diag alarm-flood|alarm-worksheet) — flood episodes (≥10 alarms/10 min), chattering, stale/standing (>24h), percent-time-in-flood vs target, and a CSV-exportable rationalization worksheet; over injected events or a live OPC-UA active-condition scan.
  • Open-format export + metrics bridge — iaiops export csv|sqlite|parquet (from the local SQLite sink; Parquet via iaiops[export]) / MCP export_data; iaiops metrics serve --port 9184 exposes Prometheus /metrics (latest tag values + counters, binds 127.0.0.1 by default) — Grafana recipe in docs/GRAFANA.md.
  • Compliance deliverables — iaiops compliance report (等保 2.0 L2/L3 status + IEC 62443 FR1–6 crosswalk + honest gap list, md/html) and iaiops compliance evidence (audit-evidence zip with hash-chain verification + manifest); MCP compliance_report / compliance_evidence_bundle. Onboarding aids, 非认证.
  • NIS2 / CRA self-assessment — iaiops compliance --framework nis2|cra and iaiops compliance report --framework nis2|cra|eu (MCP: the framework argument on compliance_frameworks / compliance_report; no new tool). NIS2 Art. 21(2)(a)–(j) and CRA Annex I Part I(1), I(2)(a)–(m), II(1)–(8), item by item: product_evidence (code-anchored mechanisms speak to the measure's central requirement — never "the measure is met", and every such row names what is left), partial_evidence (they touch it, but the central requirement is missing), gap, or organisational (product provides no evidence). NIS2 obliges entities, the CRA manufacturers; this is a product self-assessment, not a certification and not legal advice. What it still admits: no MFA or per-user identity (one shared bearer token on the HTTP transport, no TLS of its own), an audit opt-out for successful reads only (writes, denials and failures are always recorded), audit database and collected history unencrypted at rest (iaiops reset removes them but does not shred), no penetration test or fuzzing, and the SBOM, PyPI attestations and advisory process are in place but not yet exercised by a release or a report. Vulnerability handling is in SECURITY.md.
Cross-protocol brain & editions — 0.11/0.12 additions (all read-only)
  • Downtime triage copilot (downtime_triage) — composes alarm cascade + RCA verdict + PdM precursors into one triage and cross-checks whether the first-out alarm agrees with the diagnosed cause; advisory, cite-first (builds on the earlier alarm_cascade first-out reconstruction and pdm_forecast time-to-threshold early-warning).
  • Legacy-PLC maintainability (plc_program_visibility) — a risk/maintainability read over an exported ST/AWL/L5X program (size, block count, xref density, undocumented sections), never a live upload — pairs with the plc_program_outline/xref/section explainer.
  • Program ↔ field point, exact address only (plc_program_xref_config, iaiops program xref-config <file> --endpoint <name> [--live]) — which program address is which configured point: matched / in the export but not configured / configured but not named in this export. Joined only when both sides name the same address in the same address space (Siemens AWL/.scl × s7, L5X × Logix ethernetip); never by name — a label that reads like a symbol is not a match. Any other pair returns the reason it is not comparable and no lists. --live reads matched points only after the L5X and online Logix controller names agree; equal names are limited evidence, not unique identity. AWL/SCL has no CPU identity, so the CLI requires --confirm-export-origin and a CPU in RUN; MCP live reads are refused. A failed read is a gap, never a value. iaiops program doc <file> [--endpoint <name>] --out x.html turns the same export into one self-contained, deterministic HTML document (blocks, variables, I/O list, cross-reference, call graph, change history, field cross-reference) — no LLM, nothing written back into the program.
  • Per-edition tool modules (EDITION_MODULES in mcp_server/profiles.py) — a named edition can carry its own @mcp.tool group that loads only when that edition is selected — never for a bare protocol key and never in the always-on brain, so edition-specific tools stay off other surfaces and don't inflate the base. Every edition tool is read-only, cite-first, advisory:
    • warehouse — line_bottleneck (Theory-of-Constraints throughput bottleneck) + sortation_health
    • clinical — isolation_room_check (负压隔离病房 pressurization) + medical_gas_check + or_environment_check
    • building — economizer_check (AHU economizer FDD) + zone_comfort
    • process — control_loop_health (PID oscillation/offset/saturation) + heat_exchanger_fouling
    • fab — spc_check (SPC control-chart rules) + defect_pareto
    • factory — changeover_analysis (SMED)
    • water — disinfection_ct + water_quality_compliance
    • renewables — pv_performance (PV string performance)
    • sensor (IAIOPS_MCP=sensor / iaiops-mcp-sensor) — sensor_import_iodd + sensor_profile_check + sensor_read_channel + sensor_profile_list + sensor_profile_show (connect, decode and read a sensor; binding a profile stays a person's edit of config.yaml)
  • Agent skills — the repo ships a router skill (skills/iaiops) plus eleven per-edition skills (iaiops-fab / iaiops-factory / iaiops-process / iaiops-building / iaiops-water / iaiops-warehouse / iaiops-clinical / iaiops-pharma / iaiops-renewables / iaiops-plcnext / iaiops-sensor) that route an agent to the right MCP server and document the tool surface.
Deployment & ecosystem fit (edge-native / Margo)

iaiops is designed to ride on a hardened, centrally-managed edge host as a portable, governed edge application — not to own the host or the fleet manager. It maps naturally onto the Margo edge-interoperability roles: the host/device is the immutable edge OS, a compliant orchestrator places workloads by desired-state, and iaiops is the OT-domain application — read-first tap + cross-protocol RCA, exposed as governed MCP tools, with an optional on-box LLM brain for a fully air-gapped diagnostic path (data never leaves the plant).

Honest status: iaiops is a natural Margo edge application but is NOT Margo-compliant yet. Signed OCI images and an rc.3 Application Package are published. The released OCI package passed the official Application Supplier CTT runner on Ubuntu 24.04; independent review found the published 0.33.0 Compose component has the wrong OCI archive format, which the CTT did not test. The correction is a next-release candidate; deployment through a real WFM/device remains 待核实 (see the validation record).

A container + application-description package lives in deploy/margo/ (hardened Dockerfile · Compose · rc.3 descriptor); per-host distribution overlays that reuse it live under deploy/ (one folder per candidate edge host).


Install

Protocol client libraries are optional extras — install only the 1–2 protocols a site actually runs (every protocol library is imported lazily; the base package installs and imports without any of them, and a call to a not-installed protocol returns a teaching error pointing at the right extra):

uv tool install "iaiops[opcua,modbus]"   # just the protocols you need
# or one per site:  pip install "iaiops[s7]"   ·   everything:  pip install "iaiops[all]"
# or a per-industry edition bundle:        pip install "iaiops[fab]"

iaiops init                 # interactive: add endpoints, store passwords encrypted
iaiops doctor               # config + per-protocol connectivity probe (point at simulators)
iaiops protocols            # the capability map

Facts

Kind
MCP server
Repo
industrial-aiops/industrial-aiops
Group
Uncategorized
Stars
13
License
MIT
Language
Python
Last push
2026-11-09
MCP Registry
io.github.industrial-aiops/iaiops
Topics
agent-skills, ai-ops, iiot, industrial-automation, mcp, modbus, opc-ua, ot, plc, scada

Next on this shelf

  1. 5751Homebridgeio.github.mp-consulting/homebridge-ai-kitControl Homebridge accessories and scenes, manage plugins and config.json, and read logs13
  2. 5752Agent evidenceio.github.probityai/agent-evidence-mcpOffline, read-only tools that verify AI claims against evidence and replay conformance vectors.13
  3. 5753Rasmio Company Registryio.github.sepehr071/rasmio-mcpRead-only Rasmio (rasmio.com): Iranian companies, board members, gazette ads, products, brands.13
  4. 5754Refydesign.refy/refyDesign system for agents: find components by need, check code against the real API, build themes.13
  5. 5755Skill Steward MCPio.github.Arenukvern/steward-mcpExperimental read-only Steward MCP: list/inspect actions, doctor, explain (stdio).13
  6. 5756io.github.Kumar2421/marlo-mcpio.github.Kumar2421/marlo-mcpAudit a web page for SEO and technical issues with Marlo, the open-source AI CMO. Read-only.13